Restart the boiler sequence and check for 35Vdc at the connector between the black and white wires (pin 1& 5) If 35Vdc is not present at the connector inspect the wiring harness and replace if necessary Replace the control module if wire harness replacement does not resolve the problem
Read MorePop-A-Plug® P2 High Pressure Tube Plugs PAPp2 Repair Heat Exchanger Tube Leaks without Welding When it comes to heat exchanger maintenance for shell and tube condensers and boilers you need a tube plugging solution you can rely on Pop-A-Plug P2 High Pressure Tube Plugs provide a permanent mechanical tube plugging solution for leaking heat exchanger tubes without welding eliminating
Read MoreSolitaire overseas is a One Of The Leading exporter supplier stockist and manufacturer of We Offer Repair of different sizes and materials For Having OD Of 1/4 Up to 4 We Can Even Offer Customised Sizes Of As Per Clients Requirement We have a ready stock of a wide variety Also Known As Repair to
Read MoreThe condensate trap is The purpose of the condensate trap is to gather the condensate produced by the and discharge it afterwards You might be detecting an upcoming blockage if you start hearing a gurgling noise from the In order to double-check you can go outside and see if the flue makes strange noises as well
Read Morestocks over 500000 feet of the most popular sizes and specifications of tubing at our facilities making us a leading Supplier in America for your replacement tubing and fabricated parts Below is the most current list of our inventory in both our Ringgold GA and Gonzales LA warehouses As a leading Supplier we carry
Read Morefor Heat Exchangers and Chillers seal the ends of leaking providing longer use of the Heat Exchangers Boilers and Chillers The uniform taper and the smooth surface finish assure positive sealing with minimum installation force The one-piece design of the pin plug provides an easy solution to permanent for or tubesheet holes
Read MoreA tapered should only be used when it is in an application where the pressure of the will be acting to drive the securely into the (ie: plugging of generating in the drums of a water ) We've also removed from service by capping with the use of a butt weld or socket weld cap sized to fit the
Read MoreMetal Tapered offer a low-cost and quick method of sealing leaking Our are easily installed so you can establish a positive seal with minimal driving in seconds and get your Fin-Fan® / heat exchanger or back online quickly are stocked in
Read MoreApplication Tube Plugging are used for permanent plugging of condenser and heat exchanger tubes and tubesheet holes Tapered Tube Plugs be used in some high temperature/pressure heat exchangers Tube plugs driven into leaking tubes just before heat exchanger goes back into operation
Read More